To strip, remove and discard all the existing perished torched on waterproofing mats on the main roof where the current washing lines are situated at being; SQUARE To strip, remove and discard all the existing perished torched on waterproofing mats in front of the domestic quarters which is situated on the adjacent side of the main roof being; 91 Square additional balconies in the front of the building and another small concrete roof on the lower level.
St Albans College. Library roof needs urgent waterproofing and repair. Screed concrete slab towards outlets , where necessary * Waterproof ±m² concrete slab * Supply and replace broken roof tiles * Waterproof ±m wall flashings * Screed ±m box gutters towards outlet to rectify pitch of water flow * Waterproof m box gutters * Paint UV resistant
Hello! Area above two bathrooms allows water to enter next to the wall. Flat roof with gutters on it. Main roof were fix 3+ years ago but this 5m stretch starting to create problems. <10 m2 urgently; maybe need update bigger area as well. Don't think this job is very big as a start and will take max a few hours. Thanks!
Remove plastic roof sheets Replace with sink roof sheets either 3m or 3.6 m in length I will buy the material and that will include the sink sheets as well as: 2 x 5 Ltr Cemiflex, 2 x Rolss of mm x 10m membrane, 1 Bag of Portland cement, I therefore require a quote for labour to do this job Thanks
se are two small side roofs that were built as part of a big project two years ago. On he side a skylight was added last year and even after numerous attempts to seal it the contractor has failed to sop the leaks. Depending on the wind direction and the volume of water the other side still leaks occasionally also. That side now has a deck over it now, which will need to be lifted. We would like both roofst to be rubberized.
We had water damage at the office and the existing laminated floor was flooded. We need a quotation for insurance purposes and should the claim be approved, then the supplier must also be prepared to do the installation, please. The quote as soon as possible, please and the installation also to be scheduled soon after the insurance approved the quote.
IRB waterproofing quote needed. Greetings to whom it may concern, I have a house with part of the roof being flat. The problem initially was the gutter connectors are to small for a large amount of water. Subsequently outlet avenues were made available as to alleviate the water buildup. I have had work done on the roof and recently had an assessor from outsurence asses the roof His recommendation is that a thorough waterproofing needs to be done as the waterproofing done last year is flaking and allowing some water to seep through. This needs to be sorted out and would request an assessment and quote in this regards.
So just some notes to guide you through the attachments. A - Confirmed small block parquet floor as per foto (Might be a block or two missing) B - The owner can not remember if there were parquet floor, its been 40 years... Her son say that there might be, but not % sure. C - There is only carpet on top of the concrete, we would like to know if there is a product that we can use that might tie into the parquet look for this area. I think the full floor area of the confirmed space is about : 44 square meters The un confirmed space is about : 37 square meters TV room and study is about : 16 square meters 1st quote: Restore of the confirmed area. (Including the lifting of the carpet, since I might break the floor even more) 2nd quote: Restore of the total confirmed and un confirmed area (Including the lifting of the carpet, since I might break the floor even more) 3rd quote: A suitable option that would tie in with the parquet floor look.
I have an open balcony on top of a concrete slab. Under the balcony is my scullery as well as a bedroom. Between the tiled floor and the wall around the balcony, water is leaking into the scullery and bedroom. The leaks are only just where the roof and the wall meets, not any other places on the roof. In the corner of the bedroom you can also see the damp on the wall, just opposite the one outlet of the water on the balcony.
Specification: Waterproofing to concrete retaining walls to be one layer Derbigum CG4 waterproofing membrane, with mm side laps and mm end laps, sealed to primed surfaces by means of 'torch-fusion', to receive Delta MS8 Delta MS8 preformed high density polyethylene dimpled drainage and protection layer to receive compacted fill, to engineers specification, on top of geo drainage pipe system as per engineer's specification. Waterproofing to be installed by an Approved Derbigum Contractor under a 10-year guarantee. Dimple drain to receive a cover flashing to protect waterproofing membrane from stone falling between waterproofing membrane and dimple drain during compaction and construction