Need to re wire 2 bedrooms, Launch, kitchen & Bathroom with 2 outside rooms, Bathroom & Garage. The house was an one room RDP house & it eas extended in . Ever since it was extended, electricity appliences,TV, four & Two plates stoves, fridge lights are getting damaged..In the Plasma TV & Dstv decoder where strucl by lighting & our is the only house that was struck by lighting that day. Our phone chargers & laptop chargers dont last. We are constantly repairing our electrical appliences because they aleays get burned.
The dwelling consists partly of the original timber framed & clad unit possibly constructed years ago plus 's extensions providing two enlarged bathroom, two additional bedrooms and kitchen. The existing legacy installation requires to be tested for safety/compliance. Earth resistance of a socket outlet circuit in the original timber frame & clad building is unacceptably high. Installation consists largely of conductors in steel conduit which is employed as the earth return. Some wiring consists of twin & earth cable possibly installed during the 's. The dwelling consists of lounge/dining room, three bedrooms, kitchen, bathroom, shower room & garage where a more recent DB has been installed. The property is rented to tenants.
I need a municipal electrical cable joined/ fixed. CoCT has determined there is a problem and provided me with a temorary emergency cable. The problem is under the tarred driveway according to them. See X on photo. Company must also be able to fill and retar after the work is completed or refer me to someone who can.
Remove existing light fittings and old cables. Supply and installation of 1.5mm black round cable for light fittings. Supply and Install 2.5mm cable for the plugs including double compartment power skirting (plugs). Supply and installation of 3 pir wall motion sensors. Supply and installation 10 LED x light fittings. Label DB accordingly.
I am almost % sure but needs be checked...I I am pretty sure Iam paying electricity for at least another 2 units here. Its an old original farmhouse divided into 7 units ...Mine is upstairs where probably, the main distribution board is. I have had zero (literally zero) elec. used since midnight and yet my prepaid for past week has been reflecting vast usage...I keep a record of almost every day re what appliances used, how long the geyser is on for etc this makes NO sense. Single occupant on and soared up to R to R p.m. ridiculous no stove, no longer even a table top stove...no heating geyser was off...Kettle filled once or twice a day and boiling water put in thermo flask
I need a quote to install a surge arrester. It must be as per the SANS/IEC -11 low voltage surge protection standards, installed on the main electrical distribution board and the device must: – Be a type 2 device. – Be designed to withstand at least peak surge currents of 40kA (/max). – Be wired in terms of SANS -1 Connection type 2. – Have a status indicator to indicate if the protector is operational or not. – Be installed by a registered electrician who must provide a Certificate of Compliance for the installation.
Point to Multipoint solution between Vodaworld in Midrand (Base station), Blue Hills Shopping Centre, New Chapter Bookstore and Scoop Distribution (all in Midrand). Constraints: 1. The termination speed of the fibre is 2 Gb/s at Vodaworld. 2. A tower of 12m high is available at Vodaworld, a tower of 6m high is available at Blue Hills Shopping Centre, a 4m tower at New Chapter Bookstore and a 10m tower at Scoop. 3. A minimum wireless data speed of 1 Gb/s is required, with a latency less than 15 milliseconds. 4. You can have 50m of free electric cabling at both ends.
There's an electrical fault in our home in regards to heating electrical appliances like (i.e. 2 hotplate stove, microwave, kettle) that get damaged when plugged in 3 specific wall sockets on the kitchen walls. This normally happens 4 months after the purchasing of the appliances.The 4th wall socket in the kitchen isn't giving any problems as it is used to plug the refrigerator only. All other appliances utilized in other rooms in the house don't get damaged as well as the heater which is frequently plugged in the lounge area.
Hello, we would like to get a quote for COC's to be issued at our shopping center. There are over 60 DBs and sub DBs that need to be inspected and then work done to make them compliant. Do you charge an inspection fee, and if so, what is the cost? We have 3 phase and single phase. We are located at 16 Viljoen Street, Lorentzville, Johannesburg. Thanks. PJ Henning, .
We have built a new plant growth room and request a quote for installation of cm LED white lights, with other specifications below: >Fixed on 5 individual units containing 6 shelves, where each shelf will contain 2 x daylight LED lights >Each shelf to have a power switch >The growth room to have a 24 hour timer > Please see attached image to view layout of one unit and note that the purple/blue line indicates where 2 LED lights will be placed.