Very professional and quick to respond, he knows his job and I will definitely call him back for my next project.
experts. no short cuts.
Services: Tree felling, Construction company, Gardeners, Garden irrigation, Yard designer, Garden design, Electrical repair, Landscaping and gardening, Electrical contractors, Kitchen renovation, Garden edging, Garden cleaning services, Garden paving, Electrical installation, Landscape architecture, Garden maintenance, Landscape designer, Plant maintenance, Electrical companies, House contractor, Electrical wiring, Landscape gardening, Builders, Stump removal, Electrical certificate of compliance
I have block of flat Project requiring new Single phase installation. Take one apartment would have: ●6× Lighting points ●2× Double socket outlets ●7× Single socket outlets ● 1× × Single phase DB ●1× Stove circuit ●3× Bulkhead outdoor light in day/night switch Installation type: flush mount installation
It is a 1 and a half bedroom flat. I would like an evaluation done on the wiring in the kitchen specifically. A certain plug trips the Earth Leakage constantly and I'm concerned that the wiring might not be safe anymore. Also the ceiling light in the kitchen has stopped working. Replacing the bulb with a new one did not fix the issue.
Looking for a certified electrical contractor for a new construction project. From initial City Power application to final sign off. (Labour only) Project is 18 Units. 9ground floor units and 9 first floor units in one block. 2 bedrooms/Unit. Units about 42 sqm Rough estimate per unit is as follows * 10 plug points * 7 light sockets * 5 light switches * 1 DB board * 1 Stove switch Perimeter lighting points and access gate electrification
want to know how much a new db will cost me with 2 x20amp circuit breaker and 1x10 amp circuit breakers ,40 A man circuitbreaker and one earth leakage ,to new led lights in bathroom amd bedroom . and one lightswitch for bathroom with its extetion box as it is old steel ones ,,how mich will it cost to supply and rewire db again .its only this beacuse its a outside builder at the back of my house
Garage installation 1. Small DB(E/L plus two c/b 20A and 10A) 2. 20mm pvc conduit (3) 3. 20mm 90 degree bends (5) 4. 20mm hospital saddles (10) 5. 20mm male adaptors (6) 6. 20mm couplers (3) 7. 20mm 3way junction box (3) 8. 1.5 led double fitting (1) 9. 4X4 surface mount box (2) 10. 4X4 single plug (2) 11. 4X2 surface mount box (2) 12. 4X2 two-way switch (1) 13. 4X2 double switch, one-way and two-way (1) 14. 20watt led flood light (2) Please quote me on the above-mentioned items supply plus installation Please call me for more info.
My geyser switch keeps tripping on the DB board. We live in a complex so I contacted the body corporate that sent an electrician and said the thermostat was faulty. The electrician replaced the thermostat but the problem still persists. Not sure what else the issue could be. Please advise how much it would cost to repair?
Problem: Hot water temperature too high, pipe/s making Hammering, thudding sounds. Only registered, certified plumbers' quotes will be accepted. Check thermostat & geyser pressure valve, set temperature to 55 degrees Celsius; In addition: Replace washers to bath, shower, kitchen sink, washing machine & dishwasher taps; Water Jet cleaning of water system. Secure any loose copper pipe/s. Please provide itemized quote for labour and part/s. Thank you.
Senior Phase LED Lights: 39 maintenance; 8 new installations 6 Bulbs removal and replacement 13 Disco-light bulbs replacement 1 Floodlight installation 2 Garden pole lamps replacement Foundation Phase LED Lights: 13 replacement; 2 new installation 3 Floodlights installation 1 New plug point 2 repositioning of existing lights I also need a COC
Good morning, please can you provide a quote for the following plumbing issue. There is a T junction where the sewer from one toilet runs into the pipe from the main toilet. The T junction is within about 2 metres from the main toilet and 5 metres from the second toilet. There appears to be a broken or damaged pipe in this area and this restriction is creating a blockage. It seems that the T junction will need to be replaced. There is obviously paving that needs to be removed in order to reach this section. We have previously had a plumber in who tried to clear the blockage and gave us the above information. We would like to receive a few quotes before going ahead with the repairs. Thank you. Kind regards
Wiring of a section of a house. The section will have 2 DB's, 2 geysers, a kitchen, 3 bedrooms all with en-suites, 6 other rooms. There rest of the house will be done at a later stage. Please provide material with labor quote and labor only quote. Please include the price for chasing of wall and conduit installation.