I need electrician to install a backup power system on a house. All components: batteries, inverters, wires, connectors ect will be supplied. The batteries and inverters will be installed in the garage of the house, power will run from the main db board to the inverter to charge the batteries, then back out from the batteries to the inverter to the db board into the house.
Hi there, We're buying a house in Faerie Glen PTA and are challenging the electrical compliance. We need a quote for the work needed to bring the property to compliance, plus potentially a few additional fixes, plus issue of new electrical certificate. Could you please let me know if you are interested in quoting?
Just adding 4 more W panels to tile rooftop in parallel to the existing panels. Existing deye 8kW inverter Already have 4 panels 2 schletter rails and clips, 2 x MC4's, 4mm solar red wire 25m and 11m black wire (black is probably 5m too short to complete installation back to inverter, but got 5m red?) Just require roof brackets and installation with COC.
Rewiring 8 flat unit and issue coc. 4 bachelor's and four 1bed room flat.change all stove cables from 2.5mm2 to 4mm2. Separate all geysers circuits and install isolators and earth bonding. Separate geysers and plugs mixed circuits. Install dbs for 5 units 3 has already had own dbs. Build kiosk or danger room with two dbs 1st one supply 6 units plus danger room , outside lights ,gate motor,water booster pump,cameras electric fence and 2nd db supply 2 units . Each units must hv its own db .
This the project. Rooms 1 is 3 x 3 metres: 1 ceiling light per room 1 light switch per room 2 socket outlets per room Rooms 2 is 2 x 2 metres: 1 ceiling light per room 1 light switch per room 1 socket outlet per room Rooms 1 is 5 x 7 metres: 1 ceiling light per room 1 light switch per room 2 socket outlets per room 1 wall mounted light with a switch
rewire a Relief Home with a total of sqm (25 single plug points; 15 dounble plug points; 15 single light swithes; 6 double light swithes; 4 2way light switches; complete rewiring of a DB - 3Phase and N with 3-circuits and 3-earthleakages. Three(3) 20l Heatech geysers with Solar Intelligent Controllers each (SRC8/SRC9)
Please reach out to me via email. We need a COC as we are selling our property. It is a 3 bedroom (each with 1 plug and 1 light), 2 bathroom home (each 1 lught noplugs) , open plan kitchen( 2 lights, 1 extractor fan, gas stove, no oven, DB board, 3 plugs) / lounge (2 lights, 3 plugs), hallway (1 light no plugs) with a granny flat with 1 bedroom (1 light, 2 pkugs), 1 bathroom (1 light, 1 plug) open plan kitchen / dining room( no oven nor stove, 3 plugs, 2 lights), 1 garage with only 1 plug and 1 light. 1 store room with 1 plug and 1 light. Indoor braai with 3 lights and 2 plugs.
Morning, CBSMS has been appointed by a number of local municipalities to generate income. We would like to request your help with design, equipment, management and funding for: - Cameras - Solar power - Computers - Any revenue generation proposals you may wish to propose? This is for A number of LOCAL / District MUNICIPALITIES, based on a revenue share model. Would you be able to assist? If yes, please do select a suitable date & time for us to discuss how, from: https://meetings.hubspot.com/barry-t-fryer
Hi, I need an Electrical C of C for my flat in Margate (Stralenberg block of flats). The bedroom plugs are not working, thus that must be fixed as well. The geyser was installed new approx. 3 months back and I have a C of C for the geyser installation. Let me know if you can support and by when you can support to give me the quotes? I am available on Whatsapp and email. Thank you
Repair/replace a litre solar geyser. This litre solar geyser is using geyser wise and currently does not heat the water. The diagnosis given by technician is that the system was damaged by loadshedding. I'm looking at the possibility of converting this geyser to a "solar power only" geyser.