Electric Fence Entire Perimeter m 8 Strand Wall top electric fence 50 8 Strand Square Tube Brackets (1 every 3m) 1 Energizer 1 Lightning Diverter 1 Siren HT Cable - Slimline Ferrules 6mm/ 48 Tensioner - hybrid Comp spring 48 Spring Hooks 17 Warning signs - small double sided every 10m Aluminium Wire 1.6mm 8 Earth Spikes, every 30m, 3 at energiser for each zone 80 Wall anchors 5m Conduit,connectors 1 Gate Contact Installation
1. Energizer with keypad . square tube brackets 8 lines 18- Stays mm with lugs 18- Stay clamps 5-Braided wire stainless steel 1.2mm 3- HT cable slimline black 5- Ferrules 6mm per - Tension springs 2- Spring hooks 50 per pk 2- Standard gate contact 20- Warning signs 12- Earth spikes 2- Lightning diverter
Good day. The property is m right round there are 2 motor gates. The garage is not attached to the house. The distance from where the Energizer would be mounted up to the fence is 10 meter. There are enough soil for earthing. The property fence wall is made of rock and cement. The front fence has pieces of palisade devils fork of 2,5 m each for the whole length of 56 meters. The property consist of 4 corners. The property is a Square. Xtras needed: A remote panel to reset the alarm would be good. A siren as well as a strobe light. An indicator light(LED) showing the electric fence is armed.8 Strand electric fence.
Knowledgeable person to come and do site inspection. New extension (36 m) from existing electric fence is required to be installed on top of newly installed palisade fence, with gate on street front. Connection is to be from existing energizer. Repair one or two broken earthing pegs. Assess the general condition of existing segments of electric fence. Provide a quote that specifies cost items and labour. It would be greatly appreciated.
Knowledgeable person to come and do site inspection. New extension (36 m) from existing electric fence is required to be installed on top of newly installed palisade fence, with gate on street front. Connection is to be from existing energizer. Repair one or two broken earthing pegs. Assess the general condition of existing segments of electric fence. Provide a quote that specifies cost items and labour. It would be greatly appreciated.
Five room with double garage and bathroom kitchen with two separate single plung and sitting room with two separate single plung the other three rooms each with single plung ten outside lights one plung in garage and bathroom and isolator for stove eah room with single switch and two passage switch and light in veranda
I need electrician to install a backup power system on a house. All components: batteries, inverters, wires, connectors ect will be supplied. The batteries and inverters will be installed in the garage of the house, power will run from the main db board to the inverter to charge the batteries, then back out from the batteries to the inverter to the db board into the house. When power to the house from the municipal main line cuts out the power from the batteries will kick in and power the house. Expectations: clean and maintainable job needs to be done, the work will be inspected afterward and any necessary changes will have to be made, safe and maintainable work is of priority.
In summary the main specs are: a. 34 x wiring to new lights (mostly downlighters, some external wall mounted) b. 16x wiring to plug points (std double plug) c. 1x oven Isolator, wiring 32 amps d. 1x hob isolator 20amps d. 3x air con points, isolator 15 amps e. 7x switch points f. 6 x switch points 2-way g. "making good" on and integration of existing My own diagram of the job, if this might be useful for the purpose of quoting.
Install 2 x double socket plugs (supply feed to come from back to back plug thru wall into new plug socket nr 1, and extend +/- 1.5m to 2nd new plug socket) Install 1 x light switch (3 x lever) Install 1 x new light fitting inside built in braai (with +/- 1.5m silicone wire to light switch) Wire and connect to existing connector box (+/- 6m wire) - with power supply already available in connector box for lights.
Installing electricity from scratch in a 6 roomed house with a toilet( seventh room) The dB will be in a kitchen. The lounge will have 2 plug points and 1 double switch, the kitchen will have 3 plug points and 1 double switch. The main bedroom will have 2 plug points and I switch. The second bedroom will have 1 plug point and 1 switch. Third bedroom will as well have 1 plug point and 1 switch. The fourth will have 1 plug point and 1 switch. The lounge will have 5 dull lights. The kitchen will have 6 dull lights. Other rooms will have each normal lights.