I have a section of the roof that is flat. There is a hollow depression in the roof where water collects when it rains and it eventually seeps through or floods in through an adjacent skylight. the depression must be removed and resealed. There is water ingress through a chimney that was retro fitted, which needs to be repaired.
Old roof sheeting is rusting, some sheets are almost rusted through. will need to replace the roof sheets with galvanized iron sheeting. area is aprox. 4.5m x 3.5m. Need a quote for 1) take off and remove old sheeting labour cost, 2) labour cost for putting up the new sheets, 3) quote should include cost of material as well (galvanized sheets, screws, washers etc.)
Good day, I want to fully repaint my interior of my house. Work that needs to be done: All the walls - Living room - 2 bedrooms - 2 bathrooms - Skurting - Ceiling of 1 bathroom. - Kitchen cupboard - 2 doors - Window frames The house floor sqm is 99 I would estimate the walls to be around - sqm.
The thatched roofing will be used on a lodge with gumpole structure. The size on plan = 78m2 On a slope of 45 degrees = m2 I'm looking for a square meter rate that will be applicable for other units as well. Rate should include the thatch covering, the gumpole roofing structure as well as the gumpole columns.
Garage roof is rusted through in spots, leading to water leaking through, damaging garage wall and door (see pics). Part or all of the garage roof may need replacement. Original roof is galvanised mild steel. Floor size of garage is 32m2, so roof is slightly larger than that. Roof is only slightly sloped (see pic).
Quote due by Latest 12:00 Thursday 13th May Bill of quantities: PROFILED METAL SHEETING AND ACCESSORIES 0,58mm Thick "Brownbuilt" metal sections, Klip Lok , "Galvanised AZ " roof sheeting colour "Lime white" C1S. Sheeting and accessories fixed to steel structure with galvanised "KL " clips to manufacturer's specifications including sealing strips to laps and seam stitching A Roof covering with pitches not exceeding 25 degrees and with side laps seam stitched m2 29 B Rolled edges at verge m 30 C Cover flashings mm girth m 17 D Counter flashings mm girth m 37 E Side wall flashings mm girth m 3 F Head wall flashings mm girth m 51 G mm x mm Standard fascia gutters fixed to roof sheeting with and including clips m 30 H Extra over for angle No 10 I Extra over for outlet with nozzle for and jointing to x mm diameter rainwater pipe including domical grating No 5
I haver an existing IBR roof with the following issues: Flashing removed at parapet joining at all resulting in leaks all over the roof. Pitch is too low. Wood used is and not . Wood is rotten at some places. Beam in lounge is not according to plan leading to sagging. IBR sheets is still the old solid IBR and can be taken off and put back. I am not sure what the damage is underneath
Could you please quote me on the attached plans for a house at 36 Hillary rd in Mountain Homes. I would like to know which would you recommend, a Chromadek or tiled roof. Could you give me a costing for both, and if you would include the cost of putting either up. An itemized quote would be useful (Tiles / Chromadek & with or without installation) , and the turnaround time for installation would help me plan accordingly. many thanks
I have 2 projects 1 approx 78m2 replace corrugated with ibr., check seal and repair woodwork and barge boards / facials ,almost flat roof..this is a stand alone out building . 1 approx 30 m2 shingles replace with suitable solution. Low slope 10 deg.this is an add on flat to the main house which currently leaks. I need advice on shingles or sheets for the flat. Thanks a mill
We are removing the old scatting and putting a new one (waterproof) in two parking decks and 55 pillars. The scatting is.. 1 ,4 metres long 3,5 metres wide in the parking decks Pillars 1 metres long 3,5 metres wide Old expansion joints to be removed with new watertight sealant. They must be re- tarred and waterproofed over the new sealant X6 x 7 metres X1 x 23,3 metres Grids X4 x 1,4 metres long and metres wide Drains (replacement of old drain covers with steel drain covers)... X47 Reinstate full bore drains (blanked with concrete and install new drainage pipe and new full- bore drain X7 Waterproof of skylight and replacement 6 cracked glasses X6 glasses x 1,8 metres x 1 metre Waterproof the whole pump house, walls and floors 11,2 metres x 2 metres