Good morning, please can you provide a quote for the following plumbing issue. There is a T junction where the sewer from one toilet runs into the pipe from the main toilet. The T junction is within about 2 metres from the main toilet and 5 metres from the second toilet. There appears to be a broken or damaged pipe in this area and this restriction is creating a blockage. It seems that the T junction will need to be replaced. There is obviously paving that needs to be removed in order to reach this section. We have previously had a plumber in who tried to clear the blockage and gave us the above information. We would like to receive a few quotes before going ahead with the repairs. Thank you. Kind regards
The house to be built is about square meters. I already have the plans but I need your e mail address to forward it to you. The project would be in Hermon, 24 km from Wellington and 30km from Malmesbury. On this plan we need the IBR sheeting to be one whole length sheet of say 1,5 meter wide and 19 meter long. Is such an animal realisable or do I have it miss. work on the complete roofing for this house. Thus kindly send me your e mail and you will then get the plan to compile your quote. Thanks.
General maintenance and repairs - please price separately per item listed below 1. Bedroom cupboard shelves need realignment or replaced where damaged 2. Bedroom cupboard doors need to be aligned or re-adjusted 3. Kitchen door hinges and/or door lock needs adjustment to close properly. 4. Washing lines need to be replaced (use nylon, not rope) 5. Small oil drips on the driveway need to be cleaned 6. Top kitchen corner cupboard has mould inside and the backboard needs to be cleaned or replaced 7. Inside doors needs to be fixed ( door handles and fixes loose door panelling and repaint) 8. Remove stains inside toilet bowl 9. Repaint lounge/dining room area with white paint (standard room size) 10. Check if fireplace is blocked and the cowl on the roof moves freely 11. Kitchen cupboard doors - check if hinges need adjustment and tighten loose knobs or replace missing knobs 12; Laminate flooring edging that is damaged needs to be replaced 13. Laminate flooring that can be joined back where it is moving apart without lifting the entire floor
Require a carport structure to be erected next to a braai room in my backyard. Material (steel sheets, steel lipped channel purlins, steel flashing and steel poles) are on site. The area to be covered is 6.25 x 3.45. The contractor must be able to erect steel carports, have a welder as part of his team and have power tools to cut steel purlins, steel sheet and steel poles. Roof structure requires welding.
I need a quote for painting 14 blocks of which gives you 88 Units. Block 1=12(Double Storey) Units, 10 Block Of 8 Units Double Storey, 3 Blocks Of 4 Units Double Storey, Pool Area , Club House and Guard House. The Main Colour is Elephant Hide and the boundary on the windows is beige colour and the railings, window frames, Burglar Security gates is enamel brown (Code: G18 PWD Brown)
I am looking for quotes for splitting the pipework in 6 unit complex so that each unit has its own incoming water supply and install a stop valve per unit. We require this so that we can install prepaid water meter. So if you can offer prepaid water meter as well and make it one inclusive quote , that ill be highly appreciate otherwise just the first part is the most important for now.
1. Gyser is always leaking, leaving a huge puddle outside. 2. Tap thats connected to washing machine doesn't close tightly anymore ... Constantly dripping water .. 3. Bath tap valve thingy broke into half, I tried opening the tap ... I swerved to the hot water direction and tilted the thing up and it came out
Full bathroom renovation for two bathrooms.Bathroom remodel. Remove all old file (wall and floor) and fitting (tub, toilet, basin). Replace with new fittings (walk-in shower, toilet, basin). Remove old floor and wall tiles, toilet, tub, hand basin. Replace with new tiles, walk-in shower, taps, basins etc Bathroom 1 - 22.5m2 , Floor 5m2. Bathroom 2 - 27.5m2 , Floor 7.5m2.
I Have 2 x adjoining room spaces with existing concrete slab roofing Approximately 90sqm in total. When i say slab i mean, this was not done to standard by the looks of it. When it rains it leaks and varies probably between 50 - mm thickness, butt brittle as it can be. Bought this house as is. Concrete is cracking and breaking off and pieces fall down. I would like to replace the concrete roofing with IBR sheeting. Need a new registered with Municipality drawing for the change and also would like to break through one wall which already has plinth supports in (this was a large window previously it seems). We will do the breakout and build with our own contractor.
People came and ripped my copper pipes off the wall. I've replaced most of them except my kitchen tap pipes. I'm wanting to change them to polycorp pipes connected to the previous copper pipes that I've replaced. You need 5 corner pipes with piping and a T pipe and 1 galvanized/copper pipe that needs to go through the wall.