We require a new manual change over switch installed at/near the db board. New external water proof plug point installed on the outside wall for the standby generator. Replacement of 1 x day/night sensor operating 2 x LED exterior lights. Replace 1 x "jam jar" light fitting. Remove "illegal" cable installtion to exterior plug point and run new T&E cable from exterior plug point to DB board, through newly installed conduit housed in wall.
Supply and Install Security Access Control Turnstile Gate, Description: Full height, 4-arm Single turnstile Required opening size: 1.43m wide x 2, 25m high Bi-directional suitable for internal and external installations key override for free rotation, weight kg. A straightforward. Gate will be mounted on the Wall
Supply and Install Security Access Control Turnstile Gate, Description: Full height, 4-arm Single turnstile Required opening size: 1.43m wide x 2, 25m high Bi-directional suitable for internal and external installations key override for free rotation, weight kg. A straightforward. Gate will be mounted on the Wall
we require a quote to have roughly 6 cctv cameras installed monitoring the outside of our construction site camp. We have established construction site offices next to the George Country Resort and require CCTV camera and beam installations in order to secure the premises. Please advise if you will be interested in providing a quotation. The areas to be secured are indicated on the layout below.
Supply and install DB (surface) with earth leakage, ATS, and double pole circuit breaker (10A). ESKOM supply circuit has 3 phases, with phases separated in the house. backup power supply to be done from 2 alternative points: 1. existing diesel generator (RG-I) 2. future inverter/battery/solar system
See link for plan and measements: https://1drv.ms/i/s!Amd_eMpiyfpkpKQNyNeeOYvn3sSAMg?e=5udAIn The purpose is to be a barrier around my solar battery to prevent it being bumped by a car. I am not too fussy about the steal used (it needs to be galvanised), but if a car bumps it it should hold. (it is in the garage, so will be a soft bump) It is just the frame, no mesh or cover is needed. I have probably over-engineered the design, so happy to listen if you have a better approach. I think 20mm square or angle tubing will be plenty strong.
Please, only send comparable quotes via email only....no phone calls....Please do not circulate my invoice without my explicit consent with due consideration to violations of POPIA. I need to have comparative quotes for alarm monitoring and armed response services against my current provider in Milnerton. I've attached my current invoice.
Access control for a casino 1 Mifare Readers 39 2 CR Controller 20 3 Intercom Gate Station 4 4 Intercom Monitor 4 5 Stand Alone Card Reader 1 6 KG Mag Locks and Brackets 4 7 Green Break Glass Unit 6 8 Red Break Glass Unit 3 9 Push Buttion 32 10 4 Way Mantrap Controller 2 11 4 Amp Power Supply Unit
EMAIL ONLY Work to be carried out for Compliance Certificate: Kitchen Replace 3 lever switch - cracked modules Living room Replace plug behind TV - Stuck shutters Garage Rewire garage motor plug. Currently on twin flex. 6m and install 4x4 wondabox and plug. Upstairs living room Replace fused 12v globe Replace plug at wall near steps Stuck shutters Upstairs bathroom Install 5amp isolator for extractor. Fan not running not part of compliance. Check for power. Ensuite Install x3 stream proof fittings down lights Room off ensuite Replace plug under counter and check earth connection Balcony Replace 4x2 plug - rusty. Outside back Replace 4x2 rusted plug in s15 box Roof space Install push gland at round box Install x3 isolators for geysers Install 4x4 surface mount wonda box at flush box and separate cable entries x2 Close connection at corner of roof space Upstairs roof space Install 2x4 surface wondabox in place of flush box and cover. Replace 4x4 flush box with surface mount box and separate cable entries. Bar area. Area tripping faulty transformers. Replace all with v led warm white lights X10. Outside front Install isolator for gate motor Main DB Downgrade 40amp above to 30amp Install blanks to open spaces Label joinery
The property is fully walled and will be manned after hours during the week and week ends by one guard in an observation tower and one roaming guard. We require to enhans the lighting with motion sensors, combined with curtain beams and camera observation in the observation tower. The tower guard will have a pannic connection to armed guards