Access control for a casino 1 Mifare Readers 39 2 CR Controller 20 3 Intercom Gate Station 4 4 Intercom Monitor 4 5 Stand Alone Card Reader 1 6 KG Mag Locks and Brackets 4 7 Green Break Glass Unit 6 8 Red Break Glass Unit 3 9 Push Buttion 32 10 4 Way Mantrap Controller 2 11 4 Amp Power Supply Unit
EMAIL ONLY Work to be carried out for Compliance Certificate: Kitchen Replace 3 lever switch - cracked modules Living room Replace plug behind TV - Stuck shutters Garage Rewire garage motor plug. Currently on twin flex. 6m and install 4x4 wondabox and plug. Upstairs living room Replace fused 12v globe Replace plug at wall near steps Stuck shutters Upstairs bathroom Install 5amp isolator for extractor. Fan not running not part of compliance. Check for power. Ensuite Install x3 stream proof fittings down lights Room off ensuite Replace plug under counter and check earth connection Balcony Replace 4x2 plug - rusty. Outside back Replace 4x2 rusted plug in s15 box Roof space Install push gland at round box Install x3 isolators for geysers Install 4x4 surface mount wonda box at flush box and separate cable entries x2 Close connection at corner of roof space Upstairs roof space Install 2x4 surface wondabox in place of flush box and cover. Replace 4x4 flush box with surface mount box and separate cable entries. Bar area. Area tripping faulty transformers. Replace all with v led warm white lights X10. Outside front Install isolator for gate motor Main DB Downgrade 40amp above to 30amp Install blanks to open spaces Label joinery
The property is fully walled and will be manned after hours during the week and week ends by one guard in an observation tower and one roaming guard. We require to enhans the lighting with motion sensors, combined with curtain beams and camera observation in the observation tower. The tower guard will have a pannic connection to armed guards
REQUEST FOR QUOTATION FOR FENCING MATERIALS FOR SCHOOL The matter above refers: 1. We hereby request for a quote for concrete palisade fence for a school. The type of the one on the next page2. 2. Our specifications are: m x m x 1.8m, leaving two(2) spaces of 5m each for two(2) gates. There must be a razor wire at the top. Provide two(2) sliding gates. 3. We are also prepared to have a face-to-face meeting to discuss the matter further. Your positive response is highly anticipated and appreciated
I need a clear view fence with 2.0m height, supply and installation of fence with upright posts (pipes of CHS60x2) and total height of 2.30m (2.0 above ground and 40cm below ground). The distance between the posts will be 3.00m. Includes providing all labor, materials, tools and (necessary for furnishing and installing chain link fencing. 3 layers of razor wires shall be considered at the top of fence. A gate, fence gate, 6.0 Meter wide, swing gate with 2-Panels. This is for our site Koruson, near the town of Middelburg/Noupoort in the Northern Cape Province of South Africa.
Hi Team, Please assist us with 40meters of razor wire - we are looking for a double layer of razor wire for a wall. First top razor wire to be placed on top of the wall (flat edge of the wall on top) and the second layer they want attached to the wall under the first layer for double protection. Could someone assist us with that or come through and asses the property and we take it from there? Thank you in advance. Kind regards,
• the storeroom light works but only at night as its linked to all the other communal lights in the building that only switch on at night ( all linked to a timer which is linked to the main DB , next to the storeroom). So, the storeroom light stays on all night which is a waste. As do all the garage lights as well. • We need to separate the Storeroom light switch from the timer so it can be a standalone switch. • the communal area is the one that needs to go on a daylight switch
Hello, ETHEKWINI MUNICIPALITY is going out on tender for a range of REVENUE GENERATING AND OR ENHANCEMENT INNOVATIONS (please request the tender document). If one were to install the Incoresoft software in just a few of the current cameras, substantial bylaws and traffic violations could be identified and issued. Durban has over municipal cameras and a few thousand LPR / Security cameras that could be accessed. Is this something you might be interested in? Please let me know if you can assist? Thank you Barry PS - There is a compulsory tender meeting on the 19th. Incoresoft would assist with the accredited representative letter in South Africa for the goods / services / works offered? If YES, enclose proof at the back of the tender submission. PROJECTS CATEGORIES (Service Provider to select relevant category) No. Categories Service Provider to select relevant category (X) and submit a separate Bid document for each category selected. 1 Electricity and or Electricity Losses 2 Water and or Revenue Water Losses and Sanitation 3 Waste Management 4 Real Estate 5 Development Planning 6 Property Rates 7 Grants 8 Telecommunication and network Fibre 9 Outdoor Advertising 10 Other Revenue Streams (Specify) NB: Separate proposal must be submitted for each category. Tenderer will be disqualified for not making a selection per relevant category tending for.
Supply and fit Hot rolled mm x mm Palisade Panels with Devils Fork including all angles or slotted channels for crosses. m 8 Supply and fit Hot rolled 76mm x76mm x 1.6mm Palisade poles, tar must be re-done around poles to its original surface. No 8 Supply and fit single gate to match palisade fence including lince barrel lock with 3 heavy duty hinges. No 1
Need to connect a 3 wire Franklin Electric borehole pump to a modern switching gear also from Franklin Electric - The insurance guy disconnected the pump from the old box and said the box was faulty, thus got another better box. Thus no indication which wires are connecting where, thus testing of motor to be done. Box is already fixed to the wall and only need the connection to the pump and providing of a CoC for insurance purposes/