1)Sika Cemflex reinforced waterproofing on 'Cemflex' membrane or simmilar approved applied in strict accordance with manufacturers details including waste (35m2) 2) One layer of DERBIGUM SP 4mm fully sealed to deck by torch on fusion or coldbond 90 ADHESIVE SPREAD at the rate of 1-3sqm per Litre depending on absorption of the surface. Side laps at 75mm and end laps at mm sealed together by torch on fusion. Vertical and horizontal turns should be fused to the primed surfaces; angles; outlets fillets and flat edges. All as recommended by DERBIGUM (m2) 3)Two coats of co polymer or bituminous aluminium paint (m2)
Hi there I just finished building a house I need a well-established plumber to do the following: Toilet installation or replacement, Piping installation or replacement, Shower or bathtub installation or replacement, Sink or faucet installation or replacement and Geyser installation or replacement
Move the geyser cold water vacuums breaker mm above the geyser replace leaking hot water vacuum with new one Replace 38mmx38mm battons under the geyser with the correct x38 Replace irrigation pipe with 40mm PVC on the geyser drip tray seal and secure Replace the 15mm polycop pipe with the 15mm pex pipe on the geyser pressure valve outlet and secure Secure the loose pipe in the ceiling with battons Pipe out the geyser safety valve (TP) to the outside with 22mm copper pipe and secure Replace a leak on the kitchen mixer
Replace L Geyser complete with vacuum breakers and pressure valve, Replace 4 closed coupling toilets, Repair 4 cistern kits replace, Replace underground water pipe 80 Meyers with DBE black underground water pipe from pollprop to DBE, Replace clay pipe surace underground with PVC underground pipe inclusive of 5 elbows 5 y junctions 70 Meyer pipe to be replaced, install 1 outside tap complete with 1 Meyer galvanised pipe and elbows install 3 rodding eyes replace 8 Flexi pipes, Install 4 kitchen mixers complete, Install 7 gullies complete with gully stones, install 8 ball o stops, Install 4 toilet seats, install complete urinal for men's toilet
I need a hot and cold water tap installed against the outside scullery wall. The hot and cold water piping are located against the wall within a metre at this location. The existing single concrete washing trough must be bolted to the wall. The waste pipe can be lead into the drain which is also situated within a metre distance. The washing trough rests on a footing. trough
I AM 83 YEARS OLD. Do you have a reduced rate for pensioners? Toilet repair: Cistern was leaking; daughter and gardener dismantled the parts in an attempt to repair the leak but couldn't reassemble the parts. Kitchen sink mixer - cold tap leaking so that it has flooded the cupboard. New washers? New mixer?
The toilet cistern does not stop filling when it reaches its fill and water keeps draining into the toilet which wastes water. I, therefore, need to open and close the water valve which feeds into the cistern to fill and stop filling it which is very annoying. The cistern lid is also broken so I suspect that a new toilet cistern would need to be installed. I need help, please feel free to contact me
I would like to get a quote for a plumber to come out to my house to do the following: 1. Check all taps some are leaking and some do not work at all 2. Repair or replace 2 x toilet cisterns (leaking) 3. Install and plumb new shower (Have fibre glass floor, waste, taps, shower head and doors.) 4. Supply and install hot water system to new shower. 5. Repair toilet waste pipe Our main concern are the leaks as the water account has gone up drastically. Please email only. Thanks.
Require a quote for a repair for a water meter with a leak on the incoming pipe from the main in the street, to entering the meter. The meter is old apparently and the brass or copper pipe seems to be rusty and is clearly leaking at the joint. It possibly has more leaks. I need a detailed coating of the repair in terms of materials needed and hours to repair. My voice is recovering at the moment, so I won’t be audible on the phone. Please whatsapp/email me.
Waterproofing to the balcony: Aluminum doors will be removed to the balcony Aluminum doors and frames will be wrapped in bubble wrap and stored in the garage for safekeeping until re-installation. All cement and waterproofing layers will be chopped up and removed off-site from the balcony. Rubble skip will be on-site and removed once it is filled. All existing waterproofing will be removed. mm Turn-ups will be chopped off in order to apply the waterproofing application onto the bricks. Existing outlets will be removed. New 63mm Flange outlets will be fitted to the parapet walls to allow water to discharge outside of the balcony. Screed-to-fall will be done to ensure water runs out of the outlets, and that there will be no water ponding in any areas. 50x75mm Angle will be fitted where the door will be fitted to prevent water from running back into the rooms. The waterproofing application will consist of the following: x2 Coats of Mapei-Lastic Mapei-tape to all turn-ups and corners and into the cavities. Mapei-net the flat surface x1 coat will be applied, followed by the Mapei-net and Mapei-tape being applied on top of the 1st coat. 2nd coat will be applied over all of the above-mentioned after 24 hours. Aluminum doors and frames will be re-fitted. Turn-ups and bands around the frames will be plastered to a smooth finish. Waterproofing application and plaster will be left for x3 days before the painting and tiling can commence. New tiles will be installed.