1 Standard Double Sectional Automated lift door with draughtproofing. The existing Double is of the 40 raised panel type single up and over and will remain in place until all new brickwork is completed 3 mtrs forward of existing door and new door to be fitted before removal of the old door. This is for security reasons. This installation/removal is subject to planning approval and completion of new brickwork and roofing not earlier than September/October time.
The carport needs to come from the side of the house which is about 1 meter in width, and to the way to the front of house which is about 6x6m if I'm not mistaken. I would like a quote I'm not sure what the correct measurements are at this stage. We would also like carport roof that is solid for all weather conditions especially rain, but brings in natural sunlight to the home still. Please advise. Thank you
I would like a shade carport for two cars that can be attached to the outside of my double garage. There can be no implanting with concrete due to Estate rules in order to term the port as a temporary structure. Please send me quote to cover a Fortuner and a Toyota Camry standing next to one another. Thank you.
My wooden garden gate has perished and has always been too heavy for its frame. It is in direct sunlight all day and exposed to rain so I need advice on material. I think the frame is still ok, but may need to be reinforced into the wall. The dims of the gate itself are 80cm x cm. Photos attached. I can use the existing lock but the slot would need to be cut out. I can use the existing handles. The colour is a dark brown according to estate colours. It does not need to be completely solid; it can be slotted. I can stain it providing I am given advice as to which primer and stain should be used, dependant on material of the gate. The finished item would need to be hung/lock fitted. I am not looking for a high-end product, but certainly one that would last.
Barbed wire (in rolls) to be affixed/secured to retaining structure ''wall'' in order to prevent intruders climbing retaining structure and gaining access to the property. So lengths of razor wire to be affixed to retaining structure/wall in order to prevent intruders from climbing up the structure/wall. Also required in possibly a new fence will razor wire for a small section adjacent to the retaining structure/wall.
This job is to replace an existing wooden gate that has perished. Pictures are attached. Measurements of the gate itself are 79.5cm x cm to the frame. The frame needs to be replaced too. I would need the existing handle and lock need to be transferred onto the new gate and the whole gate and frame installed. The gate need not be identical to the existing one.
One 6,4 meter gate. More or less One 2.7 meter. More or less. The two gates must meet. The long gate must be in front of the garage doors. Then other gate can be pushed open . We have a caravan that must be able to pass through the small gate. The attachment between the two gates must be able to go down when taking out the caravan.
contractor that will be able to remove the existing fence and install a new Steel Palisade fence at the Tsheesebe Primary School in Waterberg District Municipality 3. STEEL PALISADE FENCE AND ACCESSORIES SPECIFICATIONS 3.1. Installation of Steel Palisade Fencing Panels: 1.8 x 3m above ground level. 3.2. Fence bearers: 40 x 40 x 2m angle iron. These are to be placed mm from top of paling and mm from bottom of paling. (mm from ground level). These are to be welded flash with the back of the post. 3.3. Palings “Devil Fork” 21 palings per panel. 30 x 30 x 2mm steel angle iron paling 1.8m high. Paling to be inserted and firmly welded to the bearers at mm centres to be centre. Top of the paling to provide a “Devil Fork” effect and bottom will have a dove tail. 3.4. Installation of 2.4m high (76 x 76 x2 mm) Posts: 76 x 76 x 2mm steel square tubing with closing pyramid caps on top. Post must be 2.4m high and mm will be planted into concrete footing to Engineer’s design. 3.5. Installation of Palisade Gates for Pedestrian and Sliding Gate 3.5.1. Sliding Gate: 5 m wide x 1.8 m high. 40 x 40 x 2 mm 4 m wide x 1.8 m high. 40 x 40 x 2 mm Post to be founded in a concrete footing x x deep. Concrete strength to be 20Mpa (minimum) at 28 days. 3.5.2. Pedestrian gate: 1.2 m wide x 1.8 m high. 40 x 40 x 2 mm 3.5.3. Painting: Clean surface and allow to dry completely. Remove all Flux, Rust, Grease and loose material before painting. All joints must be smoothed. Apply one coat Primer for steel (red oxide) and apply one coat universal undercoat and one coat Gloss Enamel (Traffic Green as specified by the LPDE) No brush painting. 3.5.4. The School has perimeter of metres N.B. the tenderer must price for Installation Labour Only, Including the concrete footing; the fence will be supplied by the fabricators.
I've got a single door garage door which the installer bought from Doorman Vredenburg. The top part was not stable from beginning, the installer told me it was a factory fault and he will replace it for me. To make a long story short, he disappeared along with the Doorman agent in Vredenburg. I need a quote for the top part and somebody to replace it for me.
Good morning Can you please send me a quote for 4 x 2.4M x 3 M x 20 PALES PER 3 METER /SPIKES=SPEAR 30 X 30 COLDROLL ANGLE panels 1 x 2.4M x 1 M Panels 6 x 3M x 76x76 x 1.6 POST 1 x 0.9 x76x38 Rectangular Tube 1.6 Pedestrian Gate And nut and bolt for mounted all panels mounted to the post Area will be 4M x 3M Am looking for your reply