Rewiring 8 flat unit and issue coc. 4 bachelor's and four 1bed room flat.change all stove cables from 2.5mm2 to 4mm2. Separate all geysers circuits and install isolators and earth bonding. Separate geysers and plugs mixed circuits. Install dbs for 5 units 3 has already had own dbs. Build kiosk or danger room with two dbs 1st one supply 6 units plus danger room , outside lights ,gate motor,water booster pump,cameras electric fence and 2nd db supply 2 units . Each units must hv its own db .
This the project. Rooms 1 is 3 x 3 metres: 1 ceiling light per room 1 light switch per room 2 socket outlets per room Rooms 2 is 2 x 2 metres: 1 ceiling light per room 1 light switch per room 1 socket outlet per room Rooms 1 is 5 x 7 metres: 1 ceiling light per room 1 light switch per room 2 socket outlets per room 1 wall mounted light with a switch
rewire a Relief Home with a total of sqm (25 single plug points; 15 dounble plug points; 15 single light swithes; 6 double light swithes; 4 2way light switches; complete rewiring of a DB - 3Phase and N with 3-circuits and 3-earthleakages. Three(3) 20l Heatech geysers with Solar Intelligent Controllers each (SRC8/SRC9)
Please reach out to me via email. We need a COC as we are selling our property. It is a 3 bedroom (each with 1 plug and 1 light), 2 bathroom home (each 1 lught noplugs) , open plan kitchen( 2 lights, 1 extractor fan, gas stove, no oven, DB board, 3 plugs) / lounge (2 lights, 3 plugs), hallway (1 light no plugs) with a granny flat with 1 bedroom (1 light, 2 pkugs), 1 bathroom (1 light, 1 plug) open plan kitchen / dining room( no oven nor stove, 3 plugs, 2 lights), 1 garage with only 1 plug and 1 light. 1 store room with 1 plug and 1 light. Indoor braai with 3 lights and 2 plugs.
I have a light in one of the bedrooms, where the dimmer is broken. I have had electricians come in, spend 3 hours, charge me tons of money, they have replaced the dimmer, and yet the problem persists. please could you come have a look and see if you can find the fault? I also have a fountain, where the fountain mechanism has been broken. If you could have a look and see if you can fix it.
Morning, CBSMS has been appointed by a number of local municipalities to generate income. We would like to request your help with design, equipment, management and funding for: - Cameras - Solar power - Computers - Any revenue generation proposals you may wish to propose? This is for A number of LOCAL / District MUNICIPALITIES, based on a revenue share model. Would you be able to assist? If yes, please do select a suitable date & time for us to discuss how, from: https://meetings.hubspot.com/barry-t-fryer
Hi, I need an Electrical C of C for my flat in Margate (Stralenberg block of flats). The bedroom plugs are not working, thus that must be fixed as well. The geyser was installed new approx. 3 months back and I have a C of C for the geyser installation. Let me know if you can support and by when you can support to give me the quotes? I am available on Whatsapp and email. Thank you
Repair/replace a litre solar geyser. This litre solar geyser is using geyser wise and currently does not heat the water. The diagnosis given by technician is that the system was damaged by loadshedding. I'm looking at the possibility of converting this geyser to a "solar power only" geyser.
Good day, I need an urgent quote on the repair of a gate and electrical fence. We had an accident on Friday where someone hit the gate with a vehicle. Please find photos attached: The gate is off its socket and has a dint in, The access area is also broken so needs welding, One of the wires of the electrical fence is also ripped out and the gate cannot currently open with the remote. We also cannot put the fencing on. The physical address is: 23b Impala Street, Onverwaght, Lepalale I need someone to assess and quote at the address today after 14:00. Thanks,
Greetings, require a 5kwh hybrid solar inverter with 5.09kwh lithium battery - mid range- 6 solar panels w each with rails etc, solar cables 10 meters, include required components (MPPT charge controller to be bulit into inverter, switches and surge arrestors and fuses with combiner box ) all other components and about 10 meters of power cabling from main DB Box. Installation on flat torched on - roof - rails secured on wooden beans.